Strona główna » Shop » Acrel ACR10R smart meter – three-phase reverse energy meter
Acrel ACR10R smart meter – three-phase reverse energy meter
115,20 € 93,66 € netto
AC voltage 57.7V/100V(100V),220V/380V(400V)
power consumption ≤0.2VA
frequency 45hz-65hz
Environment working temperature -10 ℃-55 ℃
Storage temperature -20℃-70℃
14 in stock
SKU
Acrel ACR10R-D16TE4
CategoriesHigh voltage, High voltage, Inverter, Low voltage, Three-phase
Product description
The multifunctional busbar type electrical instrument with external Rogowski coil and split core current transformer is suitable for energy-saving remodeling projects in high-energy industries. It is also suitable for applications such as monitoring the power of the grid-connected cabinet for the distributed photovoltaic cabinet and managing the energy demand. It features no need to remove the busbar, easy connection and safe design, which saves the remodeling cost and increases the efficiency for the user.
ACR10R-D16TE4 3-phase energy meter with 3 CT clamps 16mm
3 Phase 4 Wire LCD Display
AC voltage 57.7V/100V(100V),220V/380V(400V)
power consumption ≤0.2VA
frequency 45hz-65hz
Measurement parameters: Current, voltage, frequency and power factor, active power, reactive power and apparent power
Optional Features
Total Harmonic Distortion (THD)
Multi-tariff energy metering
SOE Record
J,K,2 pulse channel,4DI+2DO or 4DI+EP
K(4DI) Pulse(2 channels)
Frequency: 0.05 Hz, Reactive Energy: 1 Current, Voltage: 0.5
Power Supply AC85-265V or DC100-350V;DC24V(±10%);DC48V(±10%) Power Consumption ≤10VA
relay output
2 NO contacts, capacity: AC 250 V / 3 A, DC 30 V / 3 A
Environment working temperature -10 ℃-55 ℃
Storage temperature -20℃-70℃
Temperature relative humidity ≤93% (non-condensing)
Altitude ≤2500m
RS485 communication, Modbus-RTU
Weight | 2 kg |
---|---|
Dimensions | 15 × 15 × 10 cm |
Additional information
3 Phase Energy Meter with 3 Terminal CT for Solar Energy Storage
The 3 Phase Din Rail Energy Meter with Open CT Split Terminals is suitable for monitoring the power of grid-connected PV power plant, energy demand management and other applications.
It is easy to install without removing the main busbar.
It can measure electrical parameters including current, voltage, active power, reactive power, apparent power, frequency, power factor.
Supports multi-tariff energy metering, 4-quadrant energy metering, harmonic analysis and energy monitoring.
“Remote signaling” and “remote control” of the circuit breaker can be implemented via a digital input and a relay output.